New solutions to save energy
New solutions to save energy
We all know, for ventilation and air-conditioning in the factory, energy costs account for a very large percentage. Therefore, finding solutions to save energy is top concern of the manufacturers to reduce costs, reduce costs and enhance competitiveness of products on the market. At the same time, it also helps to reduce energy consumption and natural resources, contributing positively to the environment protection.
Currently, the factory powertrain typically use traffic control system through the valve Bypass. This system however meet current requirements, but wasteful energy consumption by the power of the engine to reduce a fraction. The loss on the loss of this valve elicit an energy saving potential is very large.
The solution to this problem is to use the inverter to replace the valve. Against this background, the company has launched Vietnam innovative automation control solutions, combined with energy savings by automatic control system (PLC) SIEMENS through inverters MICRO - MASTER 430 pump and fan motors of the system on.
Working principle of the inverter is quite simple. First, AC power or 3 phase 1 phase is rectified and filtered into the mains 1 pm by bridge rectifier diode and capacitor. Thus, the power factor of inverter cosphi not depend on the load and worth at least 0.96. 1 pm This voltage is converted into 3-phase AC voltage symmetry through IGBT by means of pulse width modulation (PWM). Thanks to the advancement of the current technology, the switching frequency pulses can reach supersonic frequency range, reducing engine noise and reduce losses in the iron core motors. System 3-phase AC voltage at the output can change value amplitude and frequency depending stepless control mode.
For constant torque load, voltage-frequency ratio is constant. However, with the pump and fan loads, this law is a step function 4 (voltage as a function of frequency of type 4). This creates torque characteristics as a function of speed level 2, in accordance with the requirements of the pump load torque by itself is also a function of the voltage level 2. Power conversion efficiency of the inverter is very high, because the use of power semiconductor devices manufactured using modern technology.
Therefore, energy consumption is also approximately equal to the energy required by the system. For systems that do not use the inverter, the energy loss is not only caused great waste, which itself also causes significant harm to the system. The valve wears out very fast, the mechanical details on system pressure than needed, quickly tired and more perishable. Thus, it will take more costs for system maintenance.
When active, the inverter controller MM430 always only for a main pump. If actual demand is greater than its ability to work, the system will in turn launch the next backup pump until meet requirement. The boot process of this reserve pump uses only a soft starter.
Calculate the energy savings of the inverter is built on the basis of the passage of the temperature sensor to determine the optimum pump mode, guaranteed to meet the actual requirements of the system, ie the technology requirements different traffic levels, the inverter will control the motor of the pump or fan rotating at different speeds. This will help the power consumption is significantly reduced. Therefore, the output flow appropriate to the actual requirements, has not used the valve to release excess energy ...
As used valve control system has weaknesses in that case requested 80% of the traffic norms, it took up to 96% of the nominal power consumption, while just 52% inverter, ie paradigms Frequency can save 44% power. Despite the reduced flow, the energy consumption is also reduced, but losses on devices such as the valve control is still large.
When not using the van (or to the maximum valve opening available), of course, will no longer damage on valves, engine capacity was not born bigger mechanical axis needs. Inverters work on the principle of changing the frequency (with voltage changes) should ensure adequate starting torque overload even at very low speeds. Also included in the motor current does not increase, due to coordination between the voltage and frequency to keep the flux enough torque birth. Maximum starting line of drivetrain inverters with rated current only. Therefore, do not pressure drop when starting grid, ensuring that other applications are not affected.
The ability to automate the system thanks to the built-in internal PID used for closed-loop control, communication ports with RS485 automation system on the inverter. The boot process is to soften the mechanical parts of the drivetrain will be less likely to languish or breakage, ensure longevity. Therefore, the cost for system maintenance is significantly reduced.
The power factor is kept at 0.96 Cosphi, which makes grid with higher efficiency and lower costs for system reactive power compensation, ensuring continuous control modes, absolute conformity with technological demands of the wind flow. All these benefits have increased the quality of the course and huge energy savings.
This solution not only works effectively in many countries around the world which are now also being applied in Vietnam very much.