Login
Industrial blowers
.jpg)
1 - Use
Blowers, also known as industrial fans often have two types: blowers, also known as the fan (forced draft fan) and exhaust fans also called fan smoke (induced draft fan), the centrifugal fan, is boilers used in industrial plants to provide air for combustion to fuel or stove hood after the chimney. Fans are designed and manufactured at the company with the objective of minimizing power consumption, maximum performance, operate semi-automatic or fully automatic, depending on demand, easy to operate, ensuring good conditions of stability and safety.
2 - Structure
Fan is made up of the following parts:
- Case fan (the stator);
- Bakery tools (rotating part);
- Powertrain and electric motor;
- Frame and tripods;
- Shields or automatic control systems;
- The other auxiliary equipment.
3 - Key Features and Specifications
Our company provides all kinds of power and fan pressure head depending on the order of the customer. Here are the main technical characteristics of some common fan size:
| Nr. | Specifications | Unit | Item | ||||
|---|---|---|---|---|---|---|---|
| POLYTEE CFDF- 5.25 |
POLYTEE CFDF- 9.30 |
POLYTEE CFDF- 12.45 |
POLYTEE CFDF- 16.50 |
POLYTEE CFDF- 18.55 |
|||
| 1 | Flow | m3/h | 5.000 | 9.000 | 12.000 | 16.000 | 18.000 |
| 2 | The head (pressure) | mmH2O | 250 ¸ 350 | 300 ¸ 500 | 450 ¸ 650 | 500 ¸ 650 | 550 ¸ 650 |
| 3 | Overall performance | % | 75 | 75 | 75 | 72 | 72 |
| 4 | Motor power | kW | 4.5 ¸ 6.5 | 10 ¸ 17 | 20 ¸ 28.5 | 29 ¸ 40 | 37.5 ¸ 45 |
| 5 | Number of rotation | v/ph | 1470 | 1470 | 1470 | 1470 | 1470 |
| 6 | Measurement (LxW x H) | m | 1.2 x 0.7 x 1.2 | 1.3 x 0.8 x 1.4 | 1.5 x 0.9 x 1.6 | 1.8 x 1.0 x 1.6 | |
.png)