Login
Heat network operating
Heat network operating
The main task of the heat network is operated organization providing thermal energy for household consumption on an ongoing basis with the necessary quality.
Therefore, we need:
1. Work closely coordinate between the network and the devices consume.
2. Distribution steady heat on demand via consumer households and calculate the amount of heat has granted type.
3. Look after carefully carrying fixed equipment, inspection and repair in time, ensure limited and solve any problems, and damage.
4. Organization check the status of the receiver's heat consumers.
Depending on the scale of the network they split machine area. Area network is the lowest unit of the system, it is often the network management and operation of the first section thermal center.
1. Measures to detect and resolve issues
For water supply network, the signal problem is the reduced pressure at point of adjustment or neutralization. To maintain the pressure has to be increased by adding additional water than the norm value, operators must have a clear plan of action ensures find damaged spot in the shortest time
Where the additional water has increased dramatically, the worker must check the work of additional devices in about 2-3 hours. During that time the thermal regime of the network should be kept unchanged for the change (temperature) of the water volume in the system does not influence the additional water flow. If during the aforementioned additional water has increased stability, the failure to find seats. For new heat network is commissioned or operational segments were long, tattered, they must be checked first consideration. Along with network tests must also inspect the heating equipment at the station provides gain in factory. Remember that just one seat tube is leaking any leakage of condensate water brought into it so great. The detection of water leakage can network with many different methods, primarily by means of chemical analysis of hardness and alkalinity, when a water leak in the condensate network, the hardness and alkalinity condensate increased. The second method is to check the tightness of the average heat output that is comparable steam consumption and the amount of condensate return. If two different quantities of water proved many leaks in the condensate network. A third method is to observe the average water level in the heating condenser. When water leaks in the network, the average condensate heated above normal and if the valve is not working, the problem of water flow into the turbine hotkey can cause serious problems. So heated cylinders must be equipped with devices to measure water temperature signal light or sound.
In the case of average water heater stopped rising fast, there must disconnect it immediately Average heating up. Finally, check the tightness of heating equipment can be carried out by each device in turn disconnected from the network, if the device is damaged water network leaks will stop.
If testing outside bearing and check the tightness of the bottle heated seats did not detect the leak must be examined meticulously by turn interrupt each device consumes and each tube section from system system, and observe the work of these devices provide additional water, while disconnected devices damaged, additional water will be reduced dramatically, but no damage interruptions will see average pressure decreases fast.
During finding damaged seat must remain in the hydraulic network a normal mode and network water leaks must be compensated by additional water. Otherwise water KDU has been chemically treated to add additional water must be natural for the network.
After discovering the damaged spot must quickly interruption damage and resolve.
2. Corrosion
In addition to the unexpected failure occurs in separate parts of heat network are sometimes destroyed simmering slowly and the entire system. This form of destruction very dangerous because of the scale and consequences of it very large, it is corrosive condition. In the heat network has 2 types of corrosion: corrosive internal and external corrosion.
2.1. Corrosion inside
The main cause corrosion of internal surfaces of pipes due to the oxygen dissolved in water. If there is more CO2, the process of corrosion will increase.
In the path steam corrosion inside often born during pipeline stopped working for the prevention of air, when the valve on the pipe fast redundant linking with road work opened, in part below the reserve condensate will accumulate and the incident local corrosion, localized corrosion also occurs in the duct work tools with solvent is water, mostly in the water body at rest, mud or under deposition layer corrosion when locally corroded the pipe wall forming gradually penetrated hole after making tube tube unusable even though the loss of metal not much.
Corrosion rate depends on the concentration of oxygen and its diffusion rate to the metal surface. The concentration of dissolved oxygen and water temperature the greater the higher the stronger the corrosion process.
In addition to rapid corrosion due to pipe corrosion inside surface, enhancing circulation (flow) of the tube was reduced, and by creating products of corrosion damage to the pump power increases.
The corrosive liquid often deposited on the surface of removable hose that washed away under the water circulating in the pipes and then deposited, valves, measurement instruments. This phenomenon is particularly dangerous for consumption system, because the small tubes can be blocked by the corrosive products should have stopped working, although not a metal pipe corrosion.
Thus no metal losses that a large part of the damage and the operator was caused by corrosion inside the pipes.
To overcome internal corrosion should be eliminated everywhere has air into and perform additional work for the network (compensation leakage losses) and before putting the equipment into operation consumes only normal when additional water was degassed or deoxygenated.
Additional water quality has meant so much to the life of the network and the reliability of the supply of heat.
When additional water for networking large temporary hardness will form the key irritated and sludge heating equipment, ultimately increasing the hydraulic resistance and reduce the productivity of the system. One of the conditions necessary to have for the sustainable sulam and reliability of the water system additional water must be softened or hardness stability.
Due to the significant impact of water quality on the network to internal corrosion process must have an inspection regime so strict water quality, this work is carried out by selecting a sample systematically water in the manifold of thermal center. At the intermediate point of the network and in the entrance examination system consumption condition of the pipe surface by the workers of the network underway. To facilitate the work check one set of test plates in places with different characteristics of the network, for example in the supply manifold, return manifold at the end of the drainage system network receptor.
Based on the weight loss of the plate inspection can determine the intensity of corrosion of metal surfaces and through our research can determine the maximum depth of local corrosion.
In normal conditions the average corrosion depth enables not exceed 0,04 - 0,05mm / year while the local corrosion depth should not exceed 0.1 - 0.2 mm / year.
If the system has worked a long time with water containing large amounts of dissolved oxygen and has corroded inside, when transferred to work with already degassed water should pursue all corrosion deposits was formed out of the water wash system with great speed. The amount of water consumed to wash larger than normal amount of water recirculation systems consume more than 6-8 times. The washing system is conducted until the water settles out all dirty.
2.2. External corrosion
The protection for heat network from external corrosion is an important task in operation. For underground heat networks can happen of soil erosion and can be damaged by the current fragmented. Soil erosion is occurring more slowly destroyed by the electric current fragmented. However, corrosion of the more dangerous ground because it did not show the same time and can cover a large part of the network cluster. When corrosion, thermal network can be damaged when the first on a large long distance. A main source of external corrosion and moisture can contain corrosive contaminants in the soil and in the insulation. When moisture was absorbed into the outer surface of the pipe, the corrosion process generated.
To prevent corrosion on the outside, before intubation should study of soil properties and corrosion current density scattered along the tube.
In the most dangerous places need to protect well against corrosion.
.png)